Loading...
HomeMy WebLinkAboutAgenda Bill 3.C 12/06/2010A ge4qdcv Item # 3. C EFFECTIVE DATE ORDINANCE NO. 2392 N.C.S. OF ORDINANCE 1 1 troduced by Seconded by 2 3 4 5 6 7 AN ORDINANCE OF THE COUNCIL OF THE CITY OF PETALUMA 8 REPEALING'CHAPTER 17:20 OF THE PETALUMA,MUNICIPAL CODE 9 AND ADDING A NEW CHAPTER 17.20 ADOPTING 1HE "CALIFORNIA BUILDING 10 STANDARDS.CODE, TITLE 24, PART 9, 2010'CALIFORNIA FIRE CODE, 11 BASED ON THE 2009 EDITION OF THE INTERNATIONAL FIRE CODE 12 13 14 BE 1T ORDAINED BY THE COUNCIL OF THE CITY OF PETALU'MA AS FOLLOWS: 15 16 SECTION 1: Section 17.20 of the Petaluma Municipal Code, entitled "Fire Code," and the 17 underlying ordinances, are- hereby'repealed in their entirety.., 18 19 SECTION'2: Pursuant to California Health and Safety Code section 17958.7, the City 20 Council makes the factual findings set forth in "Exhibit A" attached hereto and incorporated 21 herein by reference, and finds that the amendments made in, this ordinance to the California 22 Building Standards Code, Title 24, Part 9, 2010 California Fire Code, based on the 2009 Edition of 23 the International Fire Code, are reasonably necessary because of the local climatic, geological 24 or topographical conditions set forth in said Exhibit. 25 26 SECTION 3 Section 17.20.010 of the Petaluma Municipal Code is hereby added to read 27 as follows: 28 29 17:20:010 ADOPTION OF CALIFORNIA BUILDING STANDARDS CODE, TITLE 24, 30 PART 9,20.10 CALIFORNIA, FIRE CODE, INCORPORATING THE 2009 EDITION OF THE 31 INTERNATIO.PIAL FIRE CODE 32 33 There is hereby 'adopted by the City of Petaluma for the purpose of prescribing 34 regulation s governing conditions hazardous to life, and property from fire, 35 hazardous materials or explosion, that certain Code -and Standards known as 36 the California Code of Regulations Title 24, "Par..t 9, 2010 California Fire Code 37 (CFC), incorporating the 2009 Edition of the International Fire Code, including Ordinance No. 2392 N.C.S. Page 1 1 2 3 4 5 6 7 8 9 10 11 12 Appendix Chapters4, B, C, D E, F, G, H, I, and J published by the International 'Code Council and the California .Building Standards Commission, being particularly the 2010 Edition California Fire Code (CFC) and the whole thereof, save and except such portions as are hereinafter deleted, added or amended by this chapter. Not less than one copy of said code has been and is now filed in the Office of the Clerk of the City and the same is adopted and incorporated as fully as if set out at length herein and the provisions thereof shall be controlling within the limits of the City. SECTION 4: Section 17.20.040 of the Petaluma Municipal Code is hereby added to read as follows: 1:7.20:040 - Establishment of Fire Hazard Severity Zone(s) (FHSZ) (:a) Limits related to Chapter 49 of the California Fire Code Requirements for Wildland -Urban Interface Fire Areas as amended and adopted by City of Petaluma. Chapter 49 shall apply to all real property with newly constructed buildings within the City of Petaluma located within the fire hazard severity zone as designated by the Chief and the Fire Resources Assessment.Program (FRAP). map published by Cal Fire and as amended by the Chief. A map of such areas is maintained in the office of the Fire Prevention Bureau. 20 21 22 23 24 25 26 27 28 29 30 3.1 -32 33 34 35 36 37 38 39 40 SECTION'S: Section 17.20.650 of the Petaluma Municipal Code, entitled "Amendments Made_ in the California Fire Code," is hereby added to include the following additions, amendments and deletions to the 2010 California Fire Code: CHAPTER 1 -- SCOPE AND ADMINISTRATION Section 101.1 is amended to read as follows: 101.1 - Title. This chapter shall be known as the "2010 California Fire Code," including the appendices and may be cited and referred to as such. Section 1,02:3 is amended to read as follows: 102.3 - Change of Use.or Occupancy. No change shall be made in the use or occupancy of any structure that would place the structure in a different division of the same group or occupancy or in a different group of occupancies, unless such structure is made to comply with the requirements of this code, the California Building Code as adopted by the City of Petaluma City Council (City Council), and the International Building Code. Subject to the approval of the fire code official, the use or occupancy of an existing structure shall be allowed to be Ordinance No. 2392 N.C.S. Page 2 T changed and the structure is allowed to be occupied for purposes in other 2 groups without conforming fo all the requirements of -this code, the California 3 Building Code as adopted by the City Council, and the International Building 4 Code for those groups, provided the new or proposed use is less hazardous,. 5 based-on life and fire risk, than the existing use. 6 7 Section 102.7.1 is added to read as follows: 8 9 102.7.1 - Supplemental Rules, Regulations and Standards. The fire code official is 10 authorized to render interpretations of this code and to make and enforce rules 11 and supplemental regulations and to develop Fire Prevention Standards to carry 12 outathe application and intent of its provisions. 13 14 Section 103.1:1 is added Jo read as follows: 15 16 103.1.1 - General. 'Where this code refers to the Department of Fire Prevention, 17 the division of the Fire Prevention Bureau will be inserted. Where this code refers 18 to Fire Code Official, the Fire Marshal will be inserted. 19 20 Section 104.1 amended to read as follows: 21 22 1'04:3 -,Right of Entry 23 24 (a) The Fire Chief, or his authorized representative in the performance of 25 duties herein prescribed, shall have the right to enter upon and into any and all 26 premises under his jurisdiction, at all reasonable hours for 'the purpose of 27 inspecting the same to determine whether or not the provisions of this code and 28 all applicable laws or ordinances pertaining to the protection of persons and 29 property from fire, explosion or exposure to hazardous materials are observed 30 therein. Provided, however, that an inspection warrant`, issued pursuant to Title 31, 13, Part 3 of. the Code of 'Civil Procedure be first secured where entry is refused, 32 except in an emergency situation. No owner, occupant or any other person 33 having charge, care or control of any building or premises shall fail or neglect, 34 after proper'request is made as herein provided to promptly permit entry therein 35 by the Chief; or' his :authorized representative for the purpose of inspection and 36 examination pursuant to this code. 37 38 (b) The Fire Chief, and his duly authorized representative, shall have the 39 authority to enter any building, or premises for the purpose of extinguishing or 40 controlling any fire„ performing rescue operation - investigating the existence of 41 suspected or reported fires, gas leaks or other hazardous conditions or taking any 42 other action necessary in the reasonable performance of their'duty. Ordinance No. 2392 N.C.S. Page 3 1 2 Section `104:7.2 is amended to read as follows: 3 4 1'04.7-.2 - Technical,A►ssistance. To determine the iacceptability of technologies, 5 processes, products, facilities, materials and uses attending the design, operation 6 or use of a building or premises subject to inspection by the - Fire Marshal, the Fire 7 Marshal is authorized to require the owner,or agent to provide, without charge to 8 the jurisdiction, a scope of work, technical opinion, and all the reports necessary 9 to verify compliance with the applicable codes and standards. The opinion and 10 report shall be prepared by a qualified engineer, specialist, and laboratory or fire 11 safety specialty organization acceptable to the Fire Marshal and shall analyze 12 the fire safety properties of the design, operation or use of the building or 13 premises and the facilities and appurtenances situated thereon, to recommend 14 necessary changes. The Fire Marshal is authorized to require design submittals to 15 be prepared by, and bear the stamp of, a registered design professional. 16 17 Section; 10411.4 is added to read as follows: 18 19 104.1.,.4- Charges. The expense of securing any emergency that is within the 20 responsibility for enforcement of the Fire Chief as given in,Section 104.11 is 'a 21 charge against the person who caused the emergency,. Damages and expenses 22 incurred by any public agency having jurisdiction or any public agency assisting 23 the agency having jurisdiction shall constitute a debt of such person to the City 24 and shall be collectable by the Fire Chief for proper distribution in the same 25 manner as in the case of an obligation under an expressed or implied contract. 26 Expenses as stated above shall include, but not be limited to, equipment and 27 personnel committed and any payments required by the public agency to 28 outside business firms requested by the public agencyto secure the emergency, 29 monitor remediation and clean up the site. 30 31 Section 105.1.4 is added to read as follows: 32 33 105,1.4 - New Materials and Permits. The Fire Chief and the Fire Marshal may act 34 as a committee to determine and specify any new regulated materials, and shall 35 establish processes or occupancies requiring permits in addition to those 36 enumerated in this code. The Fire Chief or designee shall post such list in a 37 conspicuous place in the office, and distribute copies thereof to interested 38 persons. Permits under this section shall be administered in accordance with 39 Section 105. 40 41 Ordinance No. 2392 N.C.S. Page 4 `1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26, 27 28 29 30 31 32 33 34 Section 105.6.8 (Table 105.6.8) is amended to read as follows: ,Table: 105.6.8 Permit Amounts for Comi)ressed Gases Type of Gas Amount cubic feet at NTP Corrosive 200 Flammable (except ' petroleum as 200 Highly toxic Any Amount Inert andsim le asphyxiant xiant 2,000 Oxidizin (including Oxygen) 200' P ro . horic Any Amount Toxic Any Amount' Section 105:6.2.1 is added'to read: 105.6.2.1 - Apartment, :;Hotel; or Motel. An operational permit is required to operate an apartment house, hotel, or motel. Section 105.6.11.1 is added to read as follows: 105.6.11.1 - Day Care. An operational permit is required to operate a day care facility with an occupant Toad of six (6) or more children. Section'105.6.29.1 is added to read as follows: 105.6.29.1 Model Rockets Rental, Sale or Operation. An.operational permit is required to operate, manufacture, import, export, possess, store, rent or sell model rockets as de_ fined Health and Safety Code Section 12519, Section 105.6.39.1 is added to read as follows: 1:05.6.39.1 - Residential and Commercial Institutional Care Occupancy. An operational permit is required to operate residential or commercial institutional care occupancy. Occupancies complying with Health and Safety Code Section 1:3235 are exempt. Section 105.6.39.2 is added to read as follows: 105.6.39.2 - Retail Sales of Fireworks. An operational permit to. engage in the sales or distribution of state - approved fireworks is required: Ordinance No. 2392 N.C.S. Page 5 1 S ection 105.7.6.1 is added to read as follows- 2 3 105.7.6.1 - Fixed ExOnguishing-System. A construction permit is required for the 4 installation of or modification to fixed extinguishing systems including but not 5 limited to cooking, protection of computers or other high value items or systems 6: other than fire sprinklers. 7 8 Section 105.7.10.1 is added to read as follows: 9 10 105.7.10.1 - Medical Gas Systems. A construction permit is required to install a 11 medical gas system. 12 13 Section 105.7.11 is amended to read as follows: 14 15 105.7.11 - Private Fire Hydrants. and Underground Fire Main Installations. A 16 construction permit is required for the installation of any private fire hydrants 17 and /or underground fire main to supply fire hydrant(s) and /or fire sprinklers. 18 19 Section 108.1 Js amended to read as follows: 20 21 Section 108.1 Appeals 22 (a) Appeals. Whenever the Fire Chief disapproves an application or refuses 23 to°grant a permit applied .for, or when it is claimed that the provisions of the 24 code do not apply or that the true intent and meaning of the code have been 25 misconstrued or wrongly interpreted, the applicant may appeal from the 26 decision of the Fire Chief to the board of appeals, which is designated to be 27 the board of building review as heretofore established and appointed 28 according to Chapter 1.7.08 of the Petaluma Municipal Code, within thirty (30) .29 days from the date of the decision appealed. The Fire Chief shall act as 30 secretary of the board when it is hearing appeals concerned with the Fire 31 Code. 32 (b) Fireworks Booth Sales Permits. Notwithstanding Section (a), the following 33 appeals procedure shall apply exclusively to permits for Fireworks Booths Sales 34 under this Code. Any person aggrieved by a decision of the: Fire Chief, or 35 his /her designee, to disapprove an application, refuse to grant a permit, place 36 conditions on a permit, or revoke a fireworks booth sales permit shall have a 37 right of appeal of the decision to the City Manager, or his /her designee. Such 38 appeal shall be taken by filing a written notice of appeal with the City Clerk 39 within ten (10) days of the date of the decision. The appeal shall set forth the 40 grounds for the appeal and the name and address of the person requesting Ordinance No. 2392 N.C.S. Page 6 1 the appeal,'A failure to file a timely and complete appeal shall render the Z decision final and conclusive. The City Manager shall, within ten` (10) days of the 3 filing of the appeal,.set a time and place for a hearing on the appeal. The 4 appeal shall be set no less than five (5) days after the filing of the appeal and 5 no more than sixty (60) days after the filing of the appeal.. The City Manager's 6 determination following the hearing shall be in writing and "shall contain a 7 statement of the facts upon which the determination is based. The City 8 Manager's determination shall.be sent first -class U.S. mail, postage prepaid to 9 the person requesting the appeal, not later than ten (10) days following the 10 date of such determination. the determination of the City Manager shall be 11 final and conclusive. (Ord. 2175 NCS §3, 2004: Ord. 1 997 NCS § 1 (part), 1995.) 12 13 Section 108.3 is deleted in its entirety. 14 15 Section 109.3 is amended as follows: 16 17 109.3 - Violation Penaities 18 19 (a) Any violation of the provisions of this section shall be a misdemeanor. 20 Notwithstanding the preceding sentence, a violation of the provisions of this 21 section may be charged and "prosecuted as an infraction at the discretion of 22 the City Attorney's office or other enforcing authority. 23 24 (b) A person is guilty of a separate offense for each day during which 25 he /she commits, or continues or permits a violation of this chapter, or each time 26 he /she disobeys a valid. order of an enforcement officer. 27 28 (c) Because of the serious threat of fire or injury 'posed by the use of 29 "Dangerous Fireworks" that can result from persistent or repeated failures to 30 comply with the provisions of this code and the effect of such conditions or 31 activities on the safety and the use and enjoyment of surrounding properties 32 and to the public health, safety and welfare, this Article imposes liability upon 33 the owners of residential real property for all violations of this code existing on 34 their residential real property. Each contiguous use, display and /or possession 35 shall constitute a separate violation and shall be subject to a separate 36 administrative fine. 37 38 (d) Nothing in this section shall prohibit a court from imposing restitution 39 upon any person convicted of a violation of the provisions of this section. 40 Ordinance No. 2392 N.C.S. Page 7 r 1 2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 (e) In addition to any other remedies available to -the city under any applicable state or °federal statute or pursuant to any other'lawful power the city, may possess, any violation of this chapter may be prosecuted or enforced as a nuisance and enforced by a civil court action as provided in Chapter 1.13 of the Petaluma Municipal Code or via administrative enforcement as a nuisance as provided in Chapter 1.14 of the Petaluma Municipal Code as Chapters 1.13 and 1.14 may be amended from time to time. (f) Administrative Citation pursuant to Petaluma Municipal Code Chapter 1.16. In addition to any other remedies available to the city under any applicable state or federal statute or pursuant to any- other lawful power the city may possess, any violation of this Chapter maybe enforced by administrative citation pursuant to Chapter 1.16 of the Petaluma Municipal Code as Chapter 1.16 may be amended from time to time. (g) Administrative Citation pursuant to Health & Safety Code Section 12557. In addition to any other remedies available to the city under any applicable state or federal statute or pursuant to any other lawful power the city may possess, any violation of this Chapter may be enforced by administrative citation pursuant to Health & Safety Code Section 12557 when a violation relates to the possession, use, storage, sale and /or display of those fireworks classified as dangerous fireworks as defined herein and /or the use of state - approved fireworks - as defined herein on or at dates, times and /or locations other than those permitted by this ordinance. 1. The imposition of fines related to dangerous fireworks under this section 109.3.E shall be limited to persons who possess, sell, use and /or display, or to the seizure of less than 25 pounds (gross weight) of such dangerous fireworks. 2. Fines collected pursuant to this section 109.3.G shall not be subject to Health & Safety Code section 12706, which provides that certain fines collec__ted by a court of the, state be deposited with, and disbursed by, the County Treasurer. However, the city shall provide cost reimbursement to the State Fire Marshal pursuant to regulations as adopted, or as may be adopted by the State Fire Marshal addressing the State Fire Marshal's cost for the transportation and disposal of dangerous fireworks seized by the city, which costs will be part of any administrative fine imposed. Unless and until such regulations have been adopted by the State of California, the city shall hold in trust $250 or 25% of any fine collected, whichever is greater, to cover the cost of Ordinance No. 2392 N.C.S. Page 8 1 reimbursement `to -the State Fire Marshal forthe cost of transportation 2 and'dis any dangerous fireworks seized by the city. 3 4 3. Other than as expressly modified herein, enforcement of 5. violations by administrative citation pursuant to Health & Safety Code 6 Section 12557 shall' be subject to the provisions of Petaluma Municipal 7 Code Chapter 1.16. 8 9 Section 1.09.4 is added to read as follows: 10 11 Section 101.4 - Authority to Issue, Citations. The Fire Chief and members of the 12 Fire Prevention Bureau who have the discretionary duty to enforce a statute or 13 ordinance may, pursuant to Section 836.5 of the California Penal Code and 14 subject to the provisions thereof, arrest a person without a warrant whenever 15 the Fire Chief or member of the Fire Prevention Bureau has reasonable cause to 16 believe that the person ,to be arrested has committed a violation in the 17 presence of the Fire Chief or member of the Fire Prevention Bureau which he or 18 she has discretionary dutyto enforce, and to issue a notice to appear and to 19 release such person on his or her written promise to appear in court, pursuant to 20 the provisions of Section 851-5 et seq. of the California Penal Code. 21 22 Section 1111.1 (Stop Work Order) is amended to read as follows: 23 24 111.1 - Order /Authority." Whenever the fire code official finds any work 25 regulated by this code, the Petaluma Municipal Code or the Zoning Ordinance 26 being performed in ,a manner contrary to the provisions of this code, without a 27 permit, beyond the scope of the issued permit, in violation of this code, the 28 Petaluma Municipal Code or Zoning Ordinance, or deemed as dangerous or 29 unsafe, the fire code official is authorized to issue a stop work order. 30 31 Section 111.2 is amended to read as follows: 32 33 111:2.- Issuance: The stop work order shall be in writing and shall be posted in a 34 visible location_near the location where the work is being conducted. If the 35 owner or owner's agent is not on site at the time of posting, a notice advising 36 the reasons for the stop work order issuance shall be hand delivered or mailed 37 first -class -to the owner of the property involved, or to the owner's agent, or to 38 the person doing the work. Upon issuance of a stop work order, the cited work 39 shall immediately cease. The stop work order shall state the reason for the 40 order, the conditions under which the cited work will be permitted to resume, Ordinance No. 2392 N.C.S. Page 9 1 and the, name and contact information of the official or agency issuing the -2 order. 3 .. 4 Section 111.3 is amended to read as follows: 5 6 111.3 - Emergencies /Unlawful :Continuance. Where an emergency exists, the 7 fire code official shall not be required to give written notice prior to stopping 8 work. Any person who continues to engage in any I work after having been 9 served with a stop work order, except such work as that person is directed to 10 perform to remove a violation or unsafe condition, shall be guilty of a 11 misdemeanor. 12 13 Section"I'11.4 is amended to read as follows: 14 15 111.4 - failure to Comply. Any person who shall continue,any work after having 16. been served with a stop work order, except such work as that person is directed 17 to perform to remove a violation or unsafe condition, shall be subject to the 18 penalty provisions of the City of Petaluma Municipal Codes or state law. 19 20 Section 111.4.1 is added to read as follows: 21 22 111.4.1 - Removal of Tosted Stop Work Order. Any person, who removes a 23 posted stop work order wifhout written consent of the fire code official shall be 24 guilty of a misdemeanor. 25 26 Section 111.4.2 is added to read as follows: 27 28 111.4.2 - Response Required. Violators receiving a stop work order are required 29 to respond to the Fire Prevention Bureau within two (2) business days of the 30 issued notice to receive instructions on how to rescind the order. 31 32 Section 111.4.3 is added to read as follows: 33 34 11.1.4.3 - Permit,Application Required. A fire permit application must be 35 submitted for approval within fifteen (15) working days following response to the 36 Fire Prevention Bureau. Plans will be reviewed and correction letters issued or 37 permit application approved within fifteen (15) working days of receipt by the 38 fire Prevention Bureau. A response to any correction letter must be submitted 39 within fifteen (15) working days of the date of the correction letter. Five working 40 days will be required to review this second submission and a permit approved 41 for issuance. Permits ready for issuance must be issued within five (5) working 42 days thereafter. All construction must be inspected as work progresses and Ordinance No. 2392 N.C.S. Page 10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 signed off by „ali (affected) departments within sixty (60) days of permit issuance. Section 111.4.4 is added to read as follows: 111..4.4 - Fee. An additional fee of five times the permit fee shall be added to each permit subject to a stop work order. CHAPTER 2 -- DEFINITIONS Section 202 is hereby amended to add the following definitions: 202 - General Definitions Affiliated Organization. For purposes of this Article, shall be presumed to be the following: i. Organizations incorporated under the same charter or organization and their auxiliaries if the auxiliary is incorporated under the same charter; ii. Organizations sharing the same officers and /or place of meetings and /or national parent organization; iii. Subdivisions and /or fractional divisions however named or delineated of organizations; iv. Sub - organizations, one of whose primary purpose is to provide financial and /or manpower support to a parent nonprofit organization. 27 However, different organizations affiliated with and officially recognized by any 28 elementary, junior high and /or high school and /or school district that serves, in 29 whole or in part, the residents of the City of Petaluma or any public or private 30 community college, college and /or university located within the boundaries of 31 the City of Petaluma shall not be presumed to be "affiliated organizations” 32' unless i,t cdn be'shown that'they serve the same interest area or concern (i.e., 33' boosters of high school football and boosters of high school basketball would 34 be presumed to be two different, non - affiliated organizations). 35 36 Dangerous Fireworks. Dangerous fireworks shall mean dangerous fireworks as 37 defined in Health and Safety Code sections 12505 and 12561 and-the relevant 38 sections of Title 19, California Code of Regulations, Subchapter 6, which are 39 hereby incorporated by reference. Ordinance No. 2392 N.C.S. Page 1 1 1 2 'Fireworks Booth. Fireworks booth shall mean any building, counter, or other 3, structure of a temporary nature used in the sale, offering°for sale, or display for 4 sale of ".Safe and Sane Fireworks." 5 6 Nonprofit. Organization. For the purposes of this Chapter, nonprofit organization 7 shall mean any nonprofit association, charity or corporation organized primarily 8 for veterans, patriotic, welfare, civic betterment, educational, youth 9 development or charitable purposes pursuant to Internal Revenue Code 10 Sections 501 (c) 3, 4, 6, 7, 8, 10, 19, 23, or 26, Section 501 (d), Section 501 (e); or 11 which has been issued a tax_ exempt certificate as required under the Revenue 12 and Taxation Code of the State of California; or a group which is an integral 13 part of a recognized national organization having such tax- exempt status; or a 14 nonprofit organization affiliated with and officially recognized by an 15 elementary, junior high and /or high school and /or school district that serves, in 16 whole or in part, the residents of the City of Petaluma or public and /or private 17 community college, college and /or university which is located within the 18 boundaries of the City of Petaluma. 19 20 Person. Person shall mean a natural person or a legal entity that is also an 21 owner, tenant, lessee and /or other person with any right to possession or control 22 of the property where a violation of this code occurred. 01 24 Piccolo Pete -Type Fireworks. Piccolo Pete -type fireworks are "safe and sane 25 fireworks" as defined in Health and Safety Code Section 12529 and 12562 and 26 the relevant sections of Title 19, California Code of Regulations, Subchapter 6, 27 which are hereby incorporated by reference. "Piccolo Pete -type fireworks" are 28 also known and sometimes referred to and /or labeled as, and /or have 29 substantially the same. appearance and discharge characteristics as, but are 30 not limited to: "Piccolo Pete," "Whistle Pete," "Nite Siren," "Whistling Phantom," 31 "Screaming Willy," and "Whistling Pete." 32 33 Principal, and Permanent Meeting Place. Principal and permanent meeting 34 place shall mean a permanent structure, playing field, geographic area or 35 service population which resides in or is located within'fhe City of Petaluma. 36 37 Public Display of'Fireworks. Public display of fireworks shall mean an 38 entertainment feature where the public is admitted or permitted to view the 39 display or discharge of fireworks by a licensed pyro- technician. 40 Ordinance No. 2392 N.C.S. Page 12 I Qualified.Applicant. Qualified applicant shall mean any group 'or organization 2 which. has met all of the following criteria for a continuous period of not less 3 ` than one full year preceding submittal of an application for a permit to sell. 4 ` required by °this Chapter and which continues to meet.the criteria for the 5 duration of any permit to sell issued by the City of Petaluma pursuant to this 6 Chapter. A nonprofif organization as defined in this Chapter: 7 8 i. The organization must have its principal and permanent meeting 9 place within the City; 10 ii. The organization must be one which provides direct and regular 11 community services and benefits to the residents of the City; 12 iii. The organization must have a minimum bona fide membership 13 of at least twenty (20) members who either reside in the City, are 14 employed -in the. City; or are owners or operators of a business or other 15 establishment located in the City; 16 iv. Neither the organization nor any of its officers and /or officials 17 have been found by any court or city administrative process to be in 1.8 violation of any civil or criminal local, state or federal law relating to 19 fireworks within twenty -four calendar months prior to the organization's 20 submittal of an application for a permit to sell; 21 V. The organization has not had a permit to sell fireworks revoked 22 within twenty -four months prior to the organization's submittal of an 23 application for a permit to sell. 24 25 Responsible, Person. Responsible person shall mean a person who causes a 26 violation of this Chapter to occur or allows a violation to exist or continue, by his 27 or her action or failure to act, or whose agent, employee or independent 28 contractor causes a violation to occur, or allows a violation to exist or continue. 29 There is a rebuttable presumption that the record owner of residential parcel, 30 as shown on the county's latest equalized property taxes assessment rolls, and a 31 lessee of a residential parcel has a notice of any violation existing on said 32 property. For purposes of this.Chapter, there may be more than one responsible 33 person fora violation. Any person, irrespective of age, found in violation of any 34 provision of this Chapter may be issued a citation in accordance with the 35 provisions of this Chapter. Every parent, guardian or other person, having the 36 legal care; custody or control of any person under the age of eighteen (18) 37 years, who knows or reasonably should know that a minor is in violation of this 38 Chapter„ may be issued a citation in accordance with the provisions of this 39 Chapter, in addition to any citation that may be issued to the offending minor. Ordinance No. 2392 N.C.S. Page 13 1 2 State-Approved Fireworks._ State- approved fireworks shall mean "safe and 3 sane fireworks as defined in Health and Safety Code sections 12529 and 12.562 4 and the relevant sections of Title 19, California Code of Regulations, Subchapter 5 6, which are hereby incorporated by reference. State - approved fireworks are 6 also known, and sometimes referred to, as "safe and sane fireworks ". 7 8 CHAPTER 3 - GENERAL PRECAUTIONS AGAINST FIRE 9 10 Section 304.1.2.1 is added to read as follows: 11 12 304.1.2.1 Defensible Space - Neighboring Property. Persons owning, leasing, or 13 controlling property within areas requiring defensible spaces are responsible for 14 maintaining a defensible space on the property owned, leased or controlled by 15 said person, within a distance of not less than thirty feet (30') (91.467 m) from 16 any neighboring building or.structure. Distances may modified by the Fire 17 Code Official because of a site- specific analysis based on. local conditions. 18 19 CHAPTER 5 - FIRE SERVICE FEATURES 20 21 Section 501.1 is amended to read as follows: 22 23 501.1 - Scope. Fire service for buildings, structures and premises shall comply 24 with this chapter. This section applies to residential and commercial 25 developments. Single family residential projects.in approved rural areas shall 26 comply with the Fire Safety Standards. Design and construction shall be in 27 accordance with the - .following sections, unless otherwise authorized by the Fire 28 Code Official in accordance with Section 104.9 - Alternative Materials and 29 Methods. 30 31 Section 502.1 is hereby amended to include the following definitions: 32 33 Fire Apparatus Access Road. A road that provides fire apparatus access from a 34 fire station to a facility, building or portion thereof. This is a general term inclusive 35 of all other terms such as fire lane, public street, private street, and parking lot 36 lane and access roadway. Public streets may be defined by the standards of 37 the local agency having jurisdiction over the project. 38 39 Floor Area. The floor area used for calculating the required fire flow shall be the 40 total floor area of all floor levels within the exterior walls of a structure that are 41 under the horizontal projection of the roof, except as modified in Appendix 42 Section B104 of the 2010 California Fire Code. Ordinance No. 2392 N.C.S. Page 14 1 2 , Section 503.2.6 is amended 'to read as follows: 3 4 503.2.6 - Bridges and Elevated Surfaces. Where a bridge or an elevated 5 surface is part of a fire apparatus access road, the bridge shall be constructed 6 and maintained in accordance with the American Association of State 7 Highway and Transportation Officials (AASHTO) Standard Specifications. Bridges 8 and elevated surfaces shall be designed for a live load sufficient to carry the 9 imposed loads of fire apparatus. Vehicle load limits shall be posted at both 10 entrances to bridges when required by the Fire Code Official. Where elevated 11 surfaces designed for emergency vehicle use are adjacent to surfaces which 12 are not designed for such use, approved barriers, approved signs or both shall 13 be installed and maintained when required by the Fire Code Official. 14 15 Section 503.2.6.1 is added to read: 16 17 503.2.6.1 Evaluation. All existing private bridges and elevated surfaces shall be 18 evaluated by a California licensed civil engineer experienced in structural 19 engineering or a California licensed structural engineer, for the purposes of 20 safety and weight rating, and the vehicle load limits shall be posted at both 21 entrances to bridges. Theses evaluations shall be performed at the direction of 22 the Fire Marshal. '23 24 Section 503.2.6.2 is added to read: 25 26 503.2.6.2 - Bridge Maintenance. All new and existing bridges.and elevated 27 structures providing emergency access shall be routinely evaluated and 28 maintained in accordance with the American Association of;State Highway 29 and Transportation Officials (AASHTO) Manual: "The Manual for Bridge 30 Evaluation, First Edition, 2008, published by the American Association of State 31 Highway and Transportation Officials; or other approved standard. 32 33 Section 503.2.7.1 is added to read as follows: 34 35 503.2.7.,1 - Grade Angles. The maximum allowable grade for driveways and 36 roadways used for fire apparatus access is twelve percent (12 %). Special 37 allowances up to a maximum of eighteen percent (18 %) may be granted with 38 the approval of the Fire Marshal and City Engineer. For driveways not required 39 for fire apparatus access,, provisions for increases in the grade can comply with 40 Article 20-411 of the Petaluma Zoning Ordinance. 41 Ordinance No. 2392 N.C.S. Page 15 1 Section =505.1 is, amended to read as follows: 2 3. 505.1 - Address 'Identification.' New and existing buildings shall be provided with 4 approved illuminated address numbers or letters. They shall be installed on a 5 contrasting background and be plainly visible from the street or road fronting 6 the property. Address numbers shall be Arabic numerals or alphabetic letters. 7 Where access is by means of a private road and the building cannot be 8 viewed from the public way, a monument, pole, or other approved sign or 9 means shall be used to identify the structure. Address identification shall 10 comply with'Fire Department Standards. 11 12 Section 505.1.1 is added to read as follows: 13 14 505.1.1 - One and 'Two- Family Dwellings. Numbers for one and two- family 15 dwellings shall be a minimum of four inches (4 ") (101.6mrn) high with a minimum 16 stroke width of 0.5 inches (12.7 mm). 17 18 Section 505:1.2 is added to read as follows: 19 20 505.1.2 - Numbers for OtherThon One and Two - Family Dwellings. Numbers for 21 other than one and two- family dwellings shall be a minimum of twelve inches 22 (12 ") high with a minimum stroke width of one inch (1 "). Suite and unit 23 directional numbers shall be a minimum of six inches (6 ") in height with a 24 minimum stroke width of 0.75 inches. Individual unit numbers shall be a 25 minimum of four inches (4 ") in height with a minimum of strike with of 0.5 26 inches." 27 28 Section 505.1.3 is added to read as follows: 29 30 505.1.3 Complex Directory. Where two (2) or more buildings are set back off 31 the, street in excess of one. hundred fifty feet ( 150') or when required by the Fire 32 Code Official, an approved illuminated complex directory shall be provided at 33 the main entrances to the property. 34 35 Section 506.1 is amended to read as follows: 36 37 Section 506.1 - Key Boxes. When access to or within a structure or area is 38 determined to be unduly difficult by the Fire Code Official because of secured 39 openings (doors or gates), or due to the presence of hazardous materials or fire 40 protection systems a key box shall be required to be installed at an accessible Ordinance No. 2392 N.C.S. Page 16 1 1 location., The key box shall be an approved type and contain those keys 2 necessary to;gain access.. 3 4 Section 507.3.1 is added to read as follows: 5 6 507.3.1 - Adequate`UVater Supply. Minimum fire flow for buildings shall be 7 calculated as specified, in California Fire Code Section B'1.05 of Appendix B "Fire - 8 Flow Requirements for Buildings ". If building fire flow calculations cannot be 9 made at the time of project submittal, the following fire flows shall apply. When 10 the building fire flow calculations are submitted, these flows shall be adjusted in 11 accordance with Appendix B: 12 0 Single and Two Family Residential: 1,500 GPM .13 0 Commercial, Industrial, Schools and Multi - family Residential: 2,500 14 GPM 15 Fire flows for single - family ,dwellings may be reduced to the minimum flow as 16 permitted by Appendix B so long as the residual pressure shall be a minimum of 17 twenty pounds (20 Ibs) per'square foot available for firefighting. 18 19 Section 507.5 is amended to read as follows: 20 21 507.5 Fire, Hydrant Systems. Fire hydrant systems shall comply with Sections 22 507.5.1 through 507.5.6 s and Appendix C as amended. 23. 24 Section 507.5.1 is amended to read as follows: 25 26 507.5.1 - Where Required. Where a portion of the facility or building hereafter 27 constructed or moved into or within the jurisdiction is more than 150 feet (45.179 28 m) from a hydrant on a fire apparatus access road, as measured by an 29 approved.route around the exterior of the facility or building, on -site fire 30 hydrants and mains shall be provided where required by the Fire Code Official. 31 32 Section 507:5.1 the exception is deleted. 33 34 Section 507.5:1.:1 is' , added to read as follows: 35 36 507.5.1.1 - Additional Requirements. 37 (a) Upon review of site conditions by the Fire Department, fire hydrant 38 spacing requirements may be reduced or modified. Fire hydrants shall be 39 placed along all adjoining public and private streets and Fire Department 40 access drives. Ordinance No. 239,2 N.C.S. • Page 17 1 (b) Divided streets shall have hydrants located as. required by the Fire Code 2 Official on both sides <of the street, and they shall be, staggered to prevent a 3 hydrant being placed directly across the divided street from another hydrant. 4 (c) Types of Hydrants: Hydrants shall conform to the City of Petaluma Sewer 5 and Water Design and Construction Standards. 6 7 CHAPTER 6 - -- BUILDING SERVICES AND SYSTEMS 8 9 Section 605.11 is added to read as follows: 10 11 605.11 - Solar Photovoltaic Systems. Photovoltaic power systems shall be 12 installed in accordance with this code, the California Building Code, California 13 Electrical Code and Petaluma Fire and Building Departments Standard for 14 Installation of Photovoltaic Power Systems. 15 16 CHAPTER 7 -- FIRE - RESISTANCE -RATED CONSTRUCTION 17 18 Section 705 is added to read as follows: 19 20 705 - Repair of Breaches of Non -Rated Walls /Ceiiings in Fire Zone 1. Breaches, 21 openings, holes or other broken wall and ceiling areas, in buildings in Fire Zone 1 22 (generally defined as the downtown business district.) as defined in. Section 23 17.22 of the Petaluma Municipal Code shall be repaired, restored or replaced 24 when damaged, altered, breached, penetrated, removed or improperly 25 installed. Openings /breaches can be repaired with like material such as lath 26 and plaster, sheetrock, plywood or other reasonable barrier. The intent of this 27 Section is to close openings /breaches to limit the spread of fire and products of 28 combustion in the downtown business district. 29 30 CHAPTER 9 - FIRE PROTECTION SYSTEMS 31 32 Subsection .901.7.6.1 is added to read as follows: 33 34 901.7:6.1 - Problematic and Unreliable Fire Alarms. The Fire Chief may 35 determine a fire alarm to be,unreliable upon receipt of more than three (3) 36 false alarms within a twelve =month period. Upon making such a finding, the Fire 37 Chief may order the following: 38 (a) For any nuisance alarm where the system is not restored, the Fire Chief 39 may require the system owner to provide standby personnel or take such other Ordinance No. 2392 N.C.S. Page 18 1 measures, as the Fire Chief 'deems appropriate. Such measures shall remain in '2 p lace ':until a fire department approved fire alarm maintenance firm certifies in 3' writing to the Fire Chief that the alarm system has been restored to a reliable 4 condition. The Fire Chief may require such tests as he deems necessary to 5 demonstrate the adequacy of the system. 6 7 (b) Require the owner to pay mitigation fees pursuant to the City of 8 Petaluma Fee Ordinance. 9 10 Section 903.2 is amended to read as follows: 11 . 12 903.2 - Where Required. Approved automatic sprinkler systems in new buildings 13 and structures shall be provided'in locations described in this section. 14 Additional local requirements are described in Sections 903.2.1 through 903.2.18 15 and may supersede the following requirements. The most restrictive 16 requirement shall apply. 17 18 Section 903.2.19 is added to read as follows: 19 20 903.2.19 Local Fire Spririkler System Requirements. 21 22 Section 903.2.19.1 is added to read as follows: 23 24 903.2.19.1. - System Requirements. An approved automatic fire sprinkler system 25 shall .be installed and maintained in all newly constructed buildings. 26 Exceptions 27 1. Detached Group U occupancies one thousand square feet (1,000' sq.) 28 or less. Agricultural buildings and private riding arenas as approved by the 29 Fire or Building Code Official. 30 2. Detached pool houses up to one thousand square feet (1,000' sq.) in 31 floor area within fifty feet (50') of the pool and limited to a single bathroom. 32 3. Detached non - combustible motor vehicle fuel dispensing canopies :33 classified as a Group M occupancy. 34 4. A room above a detached garage used for storage only that does not 35 contain a bathroom, cooking or refrigeration facilities. 36 5. Detached carports of noncombustible construction with non - habitable 37 spaces above. Ordinance No. 2392 N.0 :S. Page 19 1 6. Detached Group B or M occupancies five hundred square feet (500' 2' so.) or less. 3 4 Section 903.2.19.2 is added to read as follows: 5 6 903.2.19.2 - Additions - Residential. Additions to existing residential buildings 7 that increase the total square footage of existing floor area by fifty percent 8 (50 %) or greater shall meet the requirements for a newly constructed building. 9 All additions to residential buildings with an existing approved automatic 10 sprinkler system shall be required to extend the sprinkler system into the 11 addition. 12 13 Section 903.2.19.3 is added to read: 14 15 903.2.19.3 Additions w Commercial and Multi- Family Additions. Additions to 16 existing commercial buildings that increase the total square footage of existing 17 floor area by twenty -five percent (25 %) or greater shall meet -the requirements 18 for a newly constructed building. All additions to commercial buildings with an 19 existing approved automatic sprinkler system shall be required to extend the 20 sprinklers into the addition. 21 22 Section 903.2.19.4 is added to read as follows: 23 24 903.2.19.4 - Remodels Alterations, or Repairs. For alterations or repairs to 25 existing building(s) involving demolition, removal, or.repair of more than fifty 26 percent (50 %) of the structure, the building shall meet the automatic fire 27 sprinkler requirements for a newly constructed building. 28 29 Exceptions Alterations or additions made solely for the purpose of complying 30 with the American's with Disabilities Act. 31 32 Section 903.2.19.5 is,added to read: 33 3.4 .903.2.19.5 - Changes of Occupancy. When any change of occupancy occurs 35 where the proposed new occupancy classification is more hazardous based on 36 fire and life safety risks as determined by the Fire Code Official, including, but 37 not limited to, the conversion of residential buildings to condominiums the 38 building shall meet the fire sprinkler requirements for a newly constructed 39 building. 40 41 Section 903.2.19.6 is added to read: Ordinance No. 2392 N.C.S. Page 20 `1 2 3! 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 „903.2.19.6 - Residential Conversions and Additions. Fire sprinkler systems shall be installed in all,single- family dwellings that are converted to duplexes and /or multi - family dwellings, bed and breakfasts, inns, lodging houses, or similar uses. All additions to residences with an existing sprinkler system shall be required to extend the sprinkler system into the addition. Existing residences in which an addition is constructed and no fire sprinkler system has been previously installed will not be required to install a sprinkler system in either the existing structure or the addition. Section 903.2.19.7 is added to read as follows: 903.2.19.7 - 11levation_of Existing Buildings. An automatic fire extinguishing system shalt be installed throughout all existing buildings when the building is elevated 'to: three (3) or more, stories, or more than thirty -five feet (35') in height, from grade to the exposed roof. , Exceptions : An automatic fire-extinguishing system need not be provided.when the area above. thirty -five feet (35') is provided for aesthetic purposes only and is a non - habitable space. Section 903.2.19.8 is added to read: 903.2.19.8 - Installation of Automatic Fire Sprinklers in Pre- Existing Buildings (Historic Downtown Business District). (a) Geographic Boundary- Historic Downtown Business District: For the purposes of this section, the Historic Downtown Business District shall include all buildings located inside the geographic area generally formed by Kentucky Street to the west Washington Street to the north, the Petaluma River to the east, and B Street to the south. Also included in this section is 201 Washington Street (Phoenix Theater) and 132 Keller Street (formerly Tuttle Drug), as more particularly described in Figure. 1003.2.12. Ordinance No. 2392 N.C.S. Page 21 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Figtne 1009:2.12 .(b) Installation Requirements: An automatic sprinkler system conforming to the Standard for the Installation of Sprinkler Systems (NFPA.13) shall be installed in all existing buildings in the Historic Downtown Business District in accordance with the following criteria: Kentucky Street and Western. Avenue: a. In any building wherein a change of occupancy occurs. b. In any building or occupancy where the square footage of the building. or occupancy is increased or alterations to the structure are made pursuant to Section 903.2.19.3, Section 903.2.19.4, Section 903.2.19.5, Section 903.2.19.6, Section 903.2.19.7 and Section 903.2.19.8 of this ordinance. c. All buildings with basements or space. ,below street grade used for storage, business, or public use shall have automatic fire „sprinklers installed within the basements or the below street grade areas no later than December 31, 2010. d. All buildings not meeting the criteria of (a) or (b) above shall have automatic fire sprinklers installed throughout the structure, including all public, private, storage and /or concealed spaces, as defined by the Standard for the Installation of Sprinkler Systems (NFPA13) by no later than December 31, 2016. (2) Petaluma Boulevard North: Automatic fire sprinkler requirements shall not become effective until the City of Petaluma installs an Ordinance No. 2392 N.C.S. Page 22 1 appropriate sized water main and laterals to the curb lines similar to the 2 main previously installed on Kentucky Street and'Western Avenue. Upon 3 notice by 'the City' of such installation, an automatic sprinkler system 4 conforming to the Standard for the installation of Sprinkler Systems 5 (NFPA -13) shall be installed according to the following criteria: 6 a. In any building wherein a change of occupancy occurs. 7 b. In any building or occupancy where the square footage of 8 the building or is increased or alternations to the 9 structure are made pursuant to Section 903.2.19.3, Section 10 903.2.19.4, Section 903.2.19.5, Section 903.2.19.6, Section 11 903.2.1.9.7 and Section 903.2.19.8 of this ordinance. 12 c. All buildings with basements or space below street grade 13 used for storage, business or public use shall have automatic 14 fire sprinklers installed within the basements or the below 15 street grade areas, no later than December 31 of the year 16 that is six (6) years from the date of the water main 17 installation. 18 d. All buildings not meeting the criteria of. (a), or (b) above shall 19 have automatic fire sprinklers installed throughout the 20 structure, including all public, private, storage and /or 21' concealed spaces, as defined by the Standard for the 22 Installation, of Sprinklers (NFPA -13), no layer than December 23 31 of the year that is twelve (12) years from the date of the 24 water main installation. 25 e. Property Owner's Responsibility for System Installation: 26 (1) The Property Owner shall be responsible for installation 27 of the lateral service from the curb line into the 28 building. This also includes: isolation, check or other 29 valves or devices, as applicable. 30 (2) The Property Owner shall be responsible for the 31 installation of the automatic - fire sprinkler system 32 according to the Standard for the Installation of 33 Sprinkler Systems (NFPA -13). 34 f. Plans and' Specifications: Plans and Calculations (NFPA -13, 35 Chapter 8) for the service lateral and fire sprinkler system shall Ordinance No. 2392 N.C.S. Page 23 1 be submitted to and approved by the Fire Prevention Bureau 2 prior to installation of equipment and materials. 3 (1) For the Kentucky Street installations that are required 4 on or before December 31, 2010 or December 31, 5 2016, all Plans and Calculations for service lateral and 6 sprinkler systems shall be submitted no later than June 7 30, 2010 or June 30, 2016 respectively, with installation 8 and approval of work to occur prior to December 31, 9 2010 or December 31, 2016 respectively. 10 (2) For Petaluma Boulevard North installations that occur 11 in the last year of the six (6) or twelve (12) year 12 deadline (when established) after the installation of 13 the water main by the City of Petaluma, Plans and 14 Calculations shall be submitted in that last year no 15 later than June 30 of that year, with installation and 16 approval of work to occur prior to December 31 of 17 that last year. 18 19 Section 903.3 is amended as follows 20 21 903.3 - Installation Requirements. Sprinkler systems shall be designed and 22 installed, in accordance with NFPA 13; NFPA 13R (if approved by the Fire Code 23 Official); and NFPA 1.3D. Pursuant to Section 102.7.1 and Section 105.1.4 the 24 Fire Code Official may require additional sprinkler coverage to mitigate certain 25 conditions such as access - or water supply issues. 26 27 Section 903.3.1 is amended to read: 28 29 903.3.1 - Design Criteria. Fire sprinkler systems installed in buildings of 30 undetermined use shall be designed and installed to have a design density of 31 .33 gallons per minute per square foot over a minimum design area of three 32 thousand square feet (3,000' sq.). Where a subsequent occupancy change 33 requires a system with greater capacity, it shall be the building owners' 34 responsibility to upgrade the system to the required density and meet any 35 additional requirements of the Fire Code at the time of such change. 36 37 Section 903.3.7 is amended to read as follows: 38 39 903.3.7 - Fire Department Connections. The location of fire department 40 connections (FDC's) shall be approved by the Fire Code Official. Approved Ordinance No. 2392 N.C.S. Page 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 °20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 locking caps shall be provided on all newly installed FDC's�.and on any' existing FD.C's found to be vandalized. Section 903.4 is amended to read as follows: 903.4 - Sprinkler System Monitoring and Alarms. Except for Group R, Division 3 Occupancies, all valves controlling the water supply for automatic sprinkler systems, pumps, tanks, water levels, temperatures, critical air pressure, and water flow switches shall be electronically supervised. Valves when used for standpipes are excluded from this provision unless required by the Fire Code Official. Section 903.4.2 is amended to read as follows: 903.4.2 - Alarms. One (1) exterior approved audible and visual device shall be connected to every automatic fire sprinkler system in an. approved location. Such sprinkler waterflow alarm devices shall be activated by'waterflow equivalent to the flow of a single sprinkler of the smallest orifice size installed in the system. Where a building fire alarm system is installed, actuation of the automatic fire sprinkler system shall actuate the building fire,alarm system. Every new commercial fire alarm system installed as , a sprinkler system monitoring alarm shall also function for the purpose of'evacuation, including those systems activated solely by fire sprinkler systems, so that occupants of the building shall be notified audibly and visually within each suite or building division. A minimum of one (f) device shall be located in each major suite as determined by the Fire _Marshal or building division in a, normally occupied location. Section 905.3.1 is amended to read as follows: 905.3.1 - Building Height. Class I standpipes shall be installed in buildings three stories or over in height and /or if, in the opinion of the Fire Chief, a hazard or condition exists in which the installation of standpipes would improve firefighting operations. ;Standpipes will be provided with approved outlets provided on each floor level, including the roof when roof access is provided. Section 905.9 Exception 2 is deleted. Section 907.9.6 is added to read as follows: Ordinance No. 2392 N.C.S. Page 25 1 907.9.6 False Fire Alarms. Owners of properties with a fire alarm system shall 2 maintain the system in accordance with section 907.9.5: False alarm `fees shall 3 be assessed' per the current adopted fee schedule. 4 5 CHAPTER 27 - HAZARDOUS MATERIALS 6 7 Section 2701.5.3 is added to read as follows: 8 9 2701.5.3 - Electronic Reporting. All Hazardous Material Management Plans 10 (HMMP) and Hazarclous'Material Inventory Statements (HMIS) shall be submitted 11 electronically as required by the Fire Code Official. 12 13 Section 2703.3.1 is amended to read as follows: 14 15 2703.3.1 - Unauthorized Discharges. Any suspected or actual hazardous 16 material, as defined by this code, including any actual carcinogen, which 17 escapes into the environment through an unauthorized release shall be 18 reported to the Fire Chief immediately upon discovery, regardless of whether 19 the release occurs on or off the site of the permitted facility and the following 20 procedures required in accordance with Sections 2703.1.1.1 through 2703.3.1.4 21 shall be followed. 22 23 CHAPTER 33 - EXPLOSIVES AND FIREWORKS 24 25 Section 3310 is added to read as follows: 26 27 3310 - Fireworks. Except as hereinafter provided, it shall be unlawful for any 28 person to possess, store, offer for sale, expose for sale, sell of retail, or use or 29 explode any dangerous fireworks or explode any rocket, firecracker, Roman 30 candle, squib, torpedo, torpedo cane, wire core sparkler, wooden core 31 sparkler, black cartridge, or other combustible device or explosive substance, 32 or any kind of fireworks or dangerous fireworks by whatsoever name known 33 within the City of Petaluma; provided that the Fire Chief shall have power to 34 adopt. reasonable rules and regulations for the granting of permits for 35 supervised public displays of fireworks by a public agency, fair association, 36 amusement park or other organization or for the use of fireworks by artisans in 37 pursuit of their trade. Every such use or display'shall be handled by a 38 competent operator approved by the Fire Chief, and shall be of such 39 character and so located, discharged or fired as in the opinion of the Fire Chief, 40 after proper investigation, not to be hazardous to property or endanger any 41 person. Ordinance No. 2392 N.C.S. Page 26 1 2 Exceptions: State - Approved Fireworks: It shall not be unlawful to, possess or sell, 3 within the city, state - approved fireworks and /or safe and sane fireworks as 4 defined herein. 5 6 This section shall not apply to persons, businesses or entities licensed by the 7 State Fire Marshal as a wholesaler and /or import /export concern to legally 8 possess or sell fireworks, including those prohibited by this section, within the city '9 for the primary purpose of sale and distribution outside the city. 10 11 Notwithstanding any provision of this code, the City Council, upon advice of 12 the Fire Chief, may in any;given fireworks sales year prohibit the sale and use of 13 state - approved fireworks and /or safe and sane fireworks when it is determined 14 that conditions exist in the City, including but not limited to fire weather events, 15 fuel moisture, drought, limitations on available firefighting forces and /or other 16 condition, that create an extreme danger to the public health and safety 17 and /or life and property.of the residents, businessesand visitors of the city. 18 19 3310.1 - Fireworks Conditions of Sales 20 21.. (a) It is unlawful for any person, firm, corporation, association, or 22 organization to sell or offer for sale any fireworks within the City, except as 23 expressly permitted by this ordinance. 24 25 (b) Time of Sale. Subject to the provisions of the State Fireworks Law 26 (California Health and Safety Code, Division 11, Part 2, Chapters 1 -7, Health and 27 Safety Code Sections 12500- 12801), and the provisions of this code, state 28 approved fireworks, as,defined in Section 1 2504 of the California Health and 29 Safety Code, maybe sold within the city between the hours of 10:00 a.m. and 30 9:00 p.m. on July 1 st, July 2nd, July 3rd and July 4th. Pyrotechnic displays may 31 deviate from these restrictions subject to applicable provisions of the California 32 Health, and Safety Code, and provided they are approved by the Fire Chief or 33 his designated representative 34 35 (c) Permit Required. No person, firm, corporation, association, or 36 organization.shall sell fireworks within the City unless they are a qualified 37 applicant and /or affiliated organization of a qualified applicant as defined in 38 this Chapter and have first obtained a permit therefore. Issuance of the permit 39 shall fulfill all municipal licensing requirements and fire safety conditions outlined 40 by the Fire Department. All permit applications shall be received in the Fire 41 Marshal's office by,no later than the last day of May each year. No person, firm, Ordinance No. 2392 N.C.S. Page 27 1 corporation; association or other organization, other than the qualified .2 applicant or its authorized representatives shall operate the booth for which the 3 permit is issued or share or otherwise participate in the profits of the operation of 4 such booth. 5 6 In addition to any fees established by resolution of the City Council for permit 7 application, processing, inspection and /or business licenses for any wholesale 8 or retail sales of state- approved fireworks, any qualified applicant for a permit 9 for wholesale sales of state- approved fireworks shall pay a non- refundable 10 "Public. Education and Compliance" fee, in an amount to: be established by 11 resolution of the City .Council, to cover the city's costs for enhanced public 12 education and enforcement of the regulations governing state- approved 13 fireworks set forth in this section. The "Public Education and. Compliance" fee 14 shall also include the costs associated with the cleanup and removal of 15 fireworks debris left on "public rights -of -way, and all public properties such as city 16 parks, city hall and other�city facilities. 17 18 Nonprofit organizations licensed and permitted to sell state- approved fireworks 19 in the City are required to obtain a temporary sales tax permit from the local 20 office of the State Board of Equalization. 21 22 (d) Information Reouired on Permit. Each qualified applicant for such 23 permit shall -file a written application with the Bureau of Fire: Prevention showing 24 the following information: 25 26 1. Name and address of qualified applicant. 27 2. Location where the qualified applicant proposes to sell fireworks. 28 3. Places of storage for fireworks. 29 4. Evidence that the qualified applicant meets the criteria 30 specified in this code. 31 32 (e) Organization(s) Authorized to Sell. No permit to sell state - approved fireworks shall 33 be issuad,.to any person except the following. 34 35 1;. Organizations or local community associations which 36 constitute qualified applicants and /or affiliated organizations of a 37 qualified applicant, as defined in this Chapter. 38 39 2. Any person, organization or entity which sold fireworks for profit in 40 the city for three (3) or more consecutive years, including and prior to 41 the 2007 fireworks sales period, shall be entitled (grandfathered) to Ordinance No. 2392 N.C.S. Page 28 1 apply and obtain a permit for each year after the 2007 fireworks sales 2 season 'up to qnd including the 2010 fireworks sales; year. Those for- profit 3 entities who qualify shall be allowed to continue to obtain a fireworks 4 sale permit until the 2010 sales year, provided that they continue to 5 apply for and obtain a permit to sell in each consecutive year following 6 the year 2007. For-'profit entities that are grandfathered shall not be 7 allowed to transfer„ sell, or otherwise give their right to sell fireworks to 8 any individual, organization or entity not previously named on their 9 fireworks permit; applications on or before 2007, No-for-profit entity will be 10 permitted to sell fireworks in the city after the 2010 sales year. 11 12 (f) Determination of Eligibility by Fire Chief — Right of Appeal. The Fire 13 Chief shall make a determination as to which organizations, including qualified 14 organizations, meet the criteria specified in Section 5. Any aggrieved applicant 15 may appeal the decision of the Fire Chief pursuant to Appendix Chapter 1, 16 Section 108.1. 17 18 (g) Maximum Number of Permits to Sell. The maximum number of permits to 19 sell state - approved fireworks shall not exceed a maximum of twenty -two (22) 20 booths. If the number of applications received up to and including the last day 21 of May of each year exceeds the number of permits to be issued, qualified 22 applicants which held permits to sell during the preceding,year and 23 grandfathered for - profit prior permittees under Section 5 shall have first priority 24 for the available permits. If there are any additional permits available, the Fire 25 Marshal shall forward a list of qualified applicants who did not hold permits to 26 sell in the prior year to fhe City Clerk who shall, not. later than the 5th day of 27 June, supervise an impartial ,drawing to determine an order of priority for each 28 application. Upon such determination, the City Clerk shall forward to the Fire 29 Marshal a list of applications„ numbered in order of priority drawn for 30 investigation and issuance. Permits may be issued in order of priority drawn to 31 those on the list until the maximum of twenty -two (22) booths is reached. 32 33 (h) Total Number of Booths Permitted for an Entity, Organization, or Group. 34 Fireworks sales permits shall be limited to one booth per qualified applicant. The 35 purpose "of limiting booths to one (1) per applicant'is to allow a maximum 36 number of entities, organizations, or groups to participate in fireworks sales. 37 38 If the total number of permit applications received does not exceed the 39 twenty -two (22) booth maximum, a qualified applicant may petition the Fire 40 Marshal to set up an additional booth, not to exceed a total of two (2) per 41 applicant. A grandfathered for - profit prior permittee under Section 5 may not Ordinance No. 2392 N.C.S. Page 29 1 increase for the new sales year the number of booths permitted in the 2 immediately preceding year. 3 4 If the, number of applications for multiple booths received up to and including 5 the last day of May of each year exceeds the number of permits to be issued, 6 the Fire Marshal shall iforward a list of qualified applicants who are requesting a 7 second booth to the City Clerk who shall, not later than on the 5th day of June, 8 supervise an impartial drawing to determine an order of priority for each 9 application. Upon such determination, the City Clerk shall forward to the Fire 10 Marshal a list of applications, numbered in order of priority as drawn. Additional 11 booths and permits will be awarded to each qualified applicant in order of 12 priority drawn until the maximum of twenty -two (22) booths is reached. 13 14 Multiple booth permits shall be given for that year only. The process for 15 awarding additional boof hsm per qualified applicant shall begin anew each 16 year. 17 18 (i) Insurance Requirements as Condition of Sale. Each applicant for a 19 permit shall file with the Bureau of Fire Prevention, prior to the issuance of any 20 permit, a policy of public.liability insurance with applicable coverage of at least 21 $300,000.00/500,000.00. No policy will be acceptable which contains a provision 22 allowing for a deductible amount. The city, its officers, employees, and agents 23 shall be named as additional insured on such insurance` policy or certificate of 24 insurance by a separate specific endorsement in a form acceptable to the 25 city's Risk Manager and City Attorney. 26 27 (j) Fireworks Booth — Restrictions on Sales. 28 1. No booth shall be located within twenty -five feet (25') of 29 combustible buildings and /or building openings (windows or doors) or 30 within fifty feet (50') of any flammable storage or within one hundred 31 feet (1.00') of any gasoline pump or distribution point. Location of booths 32 is contingent upon approval from the Fire Chief or designated 33 representative. 34 2. No booth shall have a floor area in excess of seven hundred fifty 35 square feet (750' sq.). Each booth shall have at least two (2) exits. Each 36 booth in excess of forty feet (40') in length shall have at least three (3) 37 exits spaced approximately equidistant apart; provided, however, that 38 in no case shall the distance between the exits exceed twenty -four feet 39 (24'). Exit doors shall not be less than twenty -four inches (24 ") wide and 40 six feet (6') in height and shall swing in the direction of exit travel. Ordinance No. 2392 N.C.S. Page 30 1 3. All weeds and combustible materials shall be cleared in and 2 around booth fora distance of at least twenty feet (20'). 3 4. "No Smoking" signs shall be posted on the booths. No smoking 4 shall be allowed within any fireworks booth. 5 5. No' person under eighteen (18) years of age shall sell or 6 participate in the sale of state- approved fireworks at such'booth. No 7 person under eighteen (18) years of age shall be permitted inside the 8 booth during hours of operation. Each booth must have an adult in 9 attendance and in charge of operations whenever the booth contains, 10 or is engaged in the sale of, fireworks. The permittee is solely responsible 11 for ensuring the, presence of said adult. For the purpose of this section, 12 the term "adult" shall mean any person so defined under California law. 13 6. All unsold stock shall be removed from the booth and located in 14 an approved area immediately after close of business on each and 15 every day of operation. 16 7. All litter shall be removed on a daily basis. 17 8. The booth shall be removed from the temporary location and all 18 litter shall be removed by noon on July 8th. 19 9. All retail sales of state- approved fireworks shall be permitted only 20 from within .a temporary booth. Sales from any other building or structure "21 are prohibited. 22 10. Approved banners or other barricades to prohibit parking within 23 twenty feet (20`) of the booth shall be provided. 24 H. No electrical devices or open flames are permitted within any 25 booth. 26 Exception A`single electronic cash register is permitted in the booth. 27 Power for device shall be provided by a heavy duty type electric 28 extension cord with a minimum of fifteen (15) amp. rating. There shall be 29 ;no signs of mechanical damage, fraying or exposed wire insulation to 30 'the cord., Approval of extension cord subject to inspection by the fire 31 Inspector. 32 33 12. Signs must be posted on each booth stating "No fireworks 34 permitted in the unincorporated areas of Sonoma or Marin Counties ". 35 Ordinance No. 2392 N.C.S. Page 31 1 13. No person shall knowingly sell fireworks to any person under 2 eighteen (I 8) 'years of- age. Proof that the fireworks booth permittee 3 demanded, °was shown, and acted in: reliance upon, bona fide 4 evidence of age and identity in any sale of fireworks prohibited by this 5 section shall be a defense to any proceedings for suspension or 6 revocation of the permittee's state - approved fireworks permit or a 7 criminal proceeding instituted by the city against the permittee for 8 violations of this section. For purposes of this section bona fide evidence 9 of age and identity of purchaser shall mean a document issued by a 10 federal, state, county or municipal government which contains a 11 photograph and date of birth of the purchaser including, but not limited 12 to, a valid California Driver's License, or Identification Card issued to a 13 member of the Armed Forces. Signs shall be posted in conspicuous 14 places on and in the booth indicating "No Fireworks Sales to Persons 15 Under the Age of 1;8 Photo I.D. Required ". 16 17 14. No person shall sleep or remain in any fireworks booth after close 18 of business each, day or at any time when the booth is closed for 19 business. 20 21 15. A fireworks booth need not comply with the provisions of the 22 Building Code of the City of Petaluma; provided, however, that every 23 fireworks booth shall be erected under the supervision of the Fire Chief 24 who shall require that the fireworks booth be constructed in a manner 25 which will reasonably ensure the safety of attendants and patrons. 26 27 16. Each fireworks booth shall be provided with a minimum of one 28 (1) model 2A 1 OBC fire extinguisher and one (1) 5- gallon pressure water 29 fire extinguisher, in good working order and easily accessible for use in 30 case of fire. 31 32 17.. No person shall smoke within twenty- five (25') of any safe 33 and sane fireworks booth. No person shall light, cause to be lighted or 34 permit to be lighted any fireworks or combustible material within'fif.ty 35 feet (50') of any state- approved fireworks booth. 36 37 (k) Limitations on Places and Hours of Discharge. 38 39 1. It shall be unlawful for any person to discharge any state - 40 approved fireworks in the city except between the hours of 10:00 a.m. to 41 11:00 p.m. on July 4th. 42 Ordinance No. 2392 N.C.S. Page 32 1 2. If shall be unlawful for any person to ignite, discharge, project or 2 otherwise fire or use, any state- approved fireworks, or permit the ignition, 3 discharge , or projection thereof, upon or over or onto the property of 4 another without the property owner's consent, or to ignite, discharge, 5 project or otherwise fire or make use of any state - approved fireworks 6 within ten feet (10') of any residence, dwelling or other structure listed as 7 a place of habitation by human beings. 8 9 3. The use of'stafe- approved fireworks in the city shall be limited to 10 private property except as otherwise _provided herein. No person shall 11 ignite or discharge any state- approved fireworks on private open areas 12 such as parks,, parking .lots or vacant property, without the property 13 owner's or his or her agent's permission. No person shall 14 ignite or discharge any state - approved fireworks on public or semi - 15 public open areas such as parks, parking lots or vacant property, 16 excluding public streets and sidewalks, except as authorized by the 17 Director of Parks and Recreation and the Fire Department, and, if 18 applicable, the' private property owner or his or her designated agent. 19 20 4. Any person who discharges state- approved fireworks on public 21 or private property shall be responsible for the removal of all spent 22 fireworks debris and litter or rubbish associated with the discharge of 23 fireworks, an,d`fordisposition thereof in an appropriate trash receptacle. 24 Spent fireworks debris shall be allowed, to cool for at least thirty (30) 25 minutes or immersed in water before discarding to a trash receptacle. 26 27 5. No state- approved fireworks shall be discharged in the Fire 28 Hazard Severity Zones (FHSZ) of the city, as established and approved by 29 the Petaluma Fire Department with the assistance of the California 30 Department of Forestry and Fire Protection and within the boundaries set 3.1 forth on the FHSZ. map as defined in Section 17.20.040 of the Petaluma 32 Municipal Code and kept on file in the Fire Marshal's Office. All fireworks 33 booths shall post a notice of such fireworks ban and a map designating 34 the FHSZ restrictions, in the form provided by the Fire Marshal's office. 35 Booth operators shall advise persons purchasing: state- approved 36 fireworks to review the notice and map and advise them of the fireworks 37 restriction& in the FHSZ. 38 39 6. Supervision of minors. It shall be unlawful for any person having 40 the care, custody or control of a minor (under eighteen (18) years of 41 age) to permit such minor to discharge, explode, fire or set off any Ordinance No. 2392 N.C.S. Page 33 1 'dangerous, illegal fireworks at any time, or to permit such minor to 2 discharge or set off any state - approved fireworks unless such minor does 3 so under the direct supervision of a person over eighteen (18) years of 4 age, and during the hours and on the day permitted by this section. 5 6 (1) Qualified Applicant Reporting Requirement. On or before November 1 st 7 of any sales year for which a qualified applicant received a sale permit, the 8 qualified applicant shall submit to the Fire Marshal a financial statement by the 9 treasurer or financial officer of the qualified applicantsetting forth the total 10 gross .receipts from the fireworks stand operated by the qualified applicant; all 11 expenses incurred and paid in connection with the purchase of fireworks and 12 the sale thereof; and to whom and for what purpose the net proceeds were or 13 will be disbursed, along with the most recent report filed by the qualified 14 applicant with the State Board of Equalization. The filing of the statement 15 required by this section with the city shall be a conditionprecedent to the 16 granting of any subsequent permit, and a permittee which fails to file such 17 statement shall not be considered a qualified applicant in any year subsequent 18 to its failure to file., 19 20 (m) Any permit issued under this section maybe revoked by the Fire Chief in 21 case of any violation of this section or any terms or conditions of the permit. The 22 City Council may revoke said permit(s) and /or prohibit fireworks sales at any 23 time it deems necessaryto protect the health, safety and 'welfare of the citizens 24 of the city. 25 26 Section 3310.1.1 is hereby added to read as follows: 27 28 3310.1.1 - Reports to Council. 29 30 (a) On an annual basis, before June 15th of each calendar year, the fire 31 department will prepare and provide to the City Council an education and 32 enforcement plan. The plan will include the following: 33 34 1. Education and enforcement program to be implemented in a 35 given year. 36 2. Other relevant information deemed necessary by the Fire 37 Marshal to provide an overview of the r city's experience in fireworks 38 enforcement relevant to that year's education and enforcement 39 programs'. 40 Ordinance No. 2392 N.C.S. Page 34 1 (b) By no later than fhe last day of Sept- ember, annually, the Fire Marshal will 2 provide to the City Council a fireworks after - action report. The report will include 3 the following: 4 5 1. An evaluation of the success or failure of the education and 6 enforcement plan. 7 8 2. Relevant incident - statistics for the period of June 17 through July 16th. 9 10 (c) All information and records which are otherwise exempt from public 11 disclosure pursuant to the Public Records Act will remain exempt from 12 disclosure, despite inclusion of any such information and /or records in an 13 education and enforcement plan and /or after action report,in order to avoid 14 any unintended effect on public safety operations. 15 16 Section 3310.2 is hereby added to read as follows: 17 18 3310.2 - Prohibition .on Sale and Use of Fireworks. It is unlawful for any person, 19 firm, corporation, association, organization or entity to sell or offer for sale any 20 fireworks within the city except as expressly permitted by this ordinance. It is 21 unlawful for any person, firm; corporation, association, organization or entity to 22 use any fireworks within the city except as expressly permitted by this 23 ordinance. 24 25 Section 3310.3 is hereby added to read as follows: •26 27 3310.3 Storage of Fireworks. The storage and use of fireworks inside buildings is 28 prohibited. 29 30 Exceptions State - approved fireworks purchased by the public for individual or 31 family use. 32 33 Section 3310:3.1 is hereby added to read as follows: 34 35 3310.3.1 - Storage of State= Approved Fireworks - Retail. The storage of state - 36 approved fireworks by those conducting retail sales.shall be in a non - 37 combustible container or maga2ine as approved by the Fire Marshal. The 38 location of said storage shall be within the City limits of Petaluma and be 39 approved by the Fire Marshal. 40 41 Section 3310.3.2 is hereby added to read as follows_ Ordinance No. 2392 N.C.S. Page 35 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33, 34 35 36 37 38 39 40 41 3310.31 - Prohibition:Against Modification and Discharge of State- Approved Fireworks. No person shall modify, tamper with, disassemble, rearrange and /or combine the contents or original packaging of any state- approved firework, nor in any way remove the original packaging labels. Section 3310.3.2.1 is hereby added to read as follows: 3310.3.2.1 Prohibitiom,Against'Possession, Use, Display or Discharge of Modified State - Approved Fireworks. No person shall possess, use, display, discharge or explode any state - approved firework that has been tampered with, disassembled and /orrearranged, nor shall any person, possess, use, display, discharge, explode or combine the contents of multiple stafe- approved fireworks, or combine, tape or change the originally intended purpose of state - approved fireworks. Section 33103.2.2 is hereby added to read as follows: 3310.3.2.2 - Prohibition Against Sale and Discharge of Piccolo Pete -Type Fireworks (a) Notwithstanding the provisions of Section 3309:2, no person shall sell, use, distribute, give away or discharge, at any time, on any day, any "Piccolo Pete - type firework" or any firework having substantially the same appearance and discharge characterisfics:as any of these. Additionally, any retail sale, gift, or donation of any "Piccolo Pete -type firework" (or any firework having substantially the same appearance and discharge characteristics as any of these) shall be a violation of this section. (b) Except as otherwise provided herein, it shall be lawful for any person to possess,and /or transport any "Piccolo Pete -type firework" within the City of Petaluma. (c) This section shall not apply to persons, businesses or entities licensed by the State Fire Marshal as a wholesaler and /or import /export concern to legally possess or sell fireworks, including those prohibited by this section, within the City for the primary purpose of sale and distribution outside the City. CHAPTER 49 - REQUIREMENTS FOR WILDLAND- URBAN INTERFACE FIRE AREAS Section 4902.1 The following definition is amended to read as follows: Ordinance No. 2392 N.C.S. Page 36 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 Wiidiand -Urban interface Fire Area: The geographical area located within any Moderate, High -or Very High Fire Severity Zone as recommended by the CDF Director pursuant to Public Resource Code Sections 4201-4204 and Government Code Sections 51175-51189 or in a High Fire Severity Zone as identified by the Petaluma FRAP. Section.4906.2 is amended to read as follows: 4906.2 - Applicability. New buildings for which a building permit is submitted on or after January 1, 2011, that are located within any Moderate, High or Very High Fire Severity Zone as designated by the Director of Cal Fire or in any Moderate, High or Very High Fire Severity Zone as.identified by the Fire Hazard Security Zone (FHSZ) map as defined in Section 17.20.020 of the Petaluma Municipal Fire Code shall comply with the following sections: (a) Section 4907.1 California Fire Code Defensible Space (moderate, high, very high); (b) Section 705A, 2010 California Building Code - Roofing (moderate, high; very high); (c) Section 706A, 2010 California Building Code - Vents (moderate, high, very high),; (d) Section. ,707A 2010 California Building Code - Exterior Covering (moderate, high, very high); (e) Section708A 2010 California Building Code - Exterior Windows and Doors (high, very high); (f) Section 709A 2010 California Building Code - Decking (high, very high); and (g) Section 710A 2010 California Building Code - Accessory Structures (high, very high). Section 4907.1 is amended to read as follows: 4907.1 - ' Defensible Space. The area within the perimeter of a parcel or development where Fire Hazard Severity Zones (FHSZ) is implemented, providing a key point of defense from any approaching fire. These areas are characterized (but not limited to) establishment and maintenance of emergency vehicle access, emergency water supplies, street names, building identification, and fuel modification measures. Ordinance No. 2392 N.C.S. Page 37 I Provisions for annual weed and brush abatement of the wildland -urban 2 interface fire area and the developed area shall be the responsibility of the 3 developer or property owner. A plan may be required that outlines the 4 provisions for weed abatement and shall be prepared by the property owner 5 and /or developer. When required, the plan shall include, but not be limited to, 6 the following elements: 7 (a) A defensible space of thirty feet (30') to one hundred feet (100'); 8 depending on grade and other factors around all structures, either manmade 9 or natural, in which material capable of allowing fire to spread unchecked must 10 be cleared, treated or modified to slow the rate and intensity of an 11 approaching wildfire. 12 (b) A ten -foot (10',) firebreak on each side of hillside roads or driveways 13 used for emergency access; such firebreaks may be landscaped with fire 14 resistive vegetation. 15 (c) Where required, fire breaks and /or disked trails up to thirty feet (30') 16 wide shall be identified on the plan and maintained throughout the fire season; 17 the location of such breaks /trails shall be approved by the Fire Code Official. 18 (d) Other fire protection measures based on best management practices 19 for wildfire exposure protection as required by the Fire Code Official. 20 21 Section 4907.2 is added read as follows: 22 23 4907.2 Ancillary Buildings and Structures. When required by the enforcing 24 agency, ancillary buildings and structures and detached accessory structures 25 shall comply with the provisions of this chapter. 26 APPENDIX B - FIRE -FLOW REQUIREMENTS FOR BUILDINGS 27 28 Section 8105.1 is amended to read as follows: 29 30 61:0 1 5.1 - One- and Two-Famiiy Dwellings. The minimum fire -flow requirements 31 for one- and two = fdmily dwellings having a fire -flow calculation area which 32 does not exceed 3,600 square feet (344.5 m2) shall be 1500 gallons per minute 33 (5678.11 L/min). Fire -flow and flow duration for dwellings having a fire -flow 34 calculation area in excess of 3,600 square feet (344.5 m2) shall not be less than 35 that specified in Table B 1051 of the 2010 California Fire Code. 36 37 Ordinance No. 2392 N.C.S. Page 38 1 Section B105.2 is amended to read as follows: 2 3 B105.2;- BUildings Other Than One- and Two-Family Dwellings. The minimum fire - 4 flow and flow duration for buildings other than one- and two- family dwellings 5 shall be as specified in Table B 105.1. 6 7 Exceptions A reduction in required fire -flow of up to fifty percent (50 %), as 8 approved, is allowed when the building is provided with an approved 9 automatic sprinkler system installed in accordance with other sections of this 10 code. The resulting fire-'flow shall not be less than fifteen hundred gallons per 11 minute (1,500 gpm) for the prescribed duration as specified in Table B 105.1. 12 13 APPENDIX C - FIRE HYDRANT LOCATIONS AND DISTRIBUTION 14 15 Section C105.1 is amended to read as follows: 16 17 C105.1 - Hydrant Spacing. The average spacing between fire hydrants shall not 18 exceed that listed in Table C105.1. 19 20 Exceptions The Fire Chief is authorized to allow deviations from this section 21 where existing hydrants provide all or a portion of the required fire hydrant 22 service. 23 24 Table C105.1 of Appendix C: ' Footnotes (f) and (g) are added to read as follows: 25 26 (f) For commercial, industrial and multifamily residential dwellings, average 27 spacing shall be no greater than three hundred feet (300'). 28 29 (g) A fire hydrant shall, be located within fifty.feet (50') of the FDC, or as 30 approved by the Fire Code Official. 31 32 APPENDIX D - FIRE APPARATUS ACCESS ROADS 33 34 Section D163.2 is amended to read as follows: 35 36 D1'03.2.- Grade. The grade of fire apparatus access roads shall be in 37 accordance with 'the. City of Petaluma standards for public streets or as 38 approved by the Fire Chief. 39 40 Ordinance No. 2392 N.C.S. Page 39 1 Section ;D103.3 is hereby amended to read as follows: 2 3 D103.3,- Turning Radius. The minimum turning radius shall be determined by the 4 Fire Code Official or as approved by local standards. 5 6 Section D103.4 is amended to read as follows: 7 8 D103.4 - Dead Ends: Dead -end fire apparatus access roads in excess of one 9 hundred fifty feet (150') (45.720 m) shall be provided with width and turnaround 10 provisions in accordance with the local agency requirements for public streets 11 or as approved by local standards. 12 13 Table D103.4 is deleted in its entirety. 14 15 Section D103.6 is amended t,o.read as follows: 16 17 D103.6 - Signs. Where required by the Fire Code Official, fire apparatus access 18 roads shall be marked with permanent NO PARKING- FIRE -LANE signs complying 19 with the California Vehicle Code and fire departmentstandards. 20 21 Section D104.2 is amended, to delete the Exception and read as follows: 22 23 D104.2 - Buildings Exceeding 62,000 Square Feet in Area. Buildings or facilities 24 having a gross building area of more than 62,000 square "feet (5,760 m2) shall be 25 provided with two (2) separate and approved fire apparatus access roads. 26 27 Section D106.1 is amended to delete the exception and read as follows: 28 29 D106.1 -. Projects having more than fifty (50) dwelling units. Multiple- family 30 residential projects having more than fifty (50) dwelling units shall be provided 31 with two (2) separate and approved fire apparatus access roads. 32 33 Section D106.2 is hereby deleted. 34 35 Section D107.1 is amended to delete Exceptions 1 and 2 and read as follows: 36 37 D107.1 - One- or Two- Family Dwelling Residential Developments. Developments 38 of one- and two- family dwellings where the number of dwelling units exceeds 39 fifty (50) shall be provided with two (2) separate and approved fire apparatus 40 access roads and shall meet the requirements of section D1.04.3. 41 Ordinance No. 2392 N.C.S. Page 40 1 SECTION 6: Section 17.20.060 of`fhe Petaluma Municipal Code is hereby added to read 2 as follows: 3 117.20.060 New Materials; Processes or Occupancies Which May Require 4 Permits. The City Manager, the Fire Chief and the Chief of the Bureau of Fire 5 Prevention shall act as a committee to determine and specify, after giving 6 affected persons an opportunity to be heard, any new materials, processes or 7 occupancies for which permits are required in addition to those now 8 enumerated in this code. The Chief of the Bureau of Fire Prevention shall post 9 such list in a conspicuous place at the Bureau of Fire Prevention and distribute 10 copies thereof to interested persons. 11 12 SECTION 7: The City Clerk is hereby directed to file this ordinance and the attached 13 findings of fact with the California Building Standards Commission. 14 15 SECTION 8: All former ordinances or parts thereof conflicting or inconsistent with the 16 provisions of this ordinance or off he Code or Standards hereby adopted are hereby repealed. 17 18 SECTION 9: If any section, subsection, sentence, clause or phrase or word of this 19 ordinance is for any reason held to be unconstitutional, unlawful or otherwise invalid by - a court 20 of competent jurisdiction, such decision shall not affect the validity of the remaining portions of 21 this ordinance. The City Council of the City of Petaluma hereby declares that it would have 22 passed and adopted this ordinance and each and all provisions thereof irrespective of the fact 23 that any one or more of said provisions be declared unconstitutional, unlawful or otherwise 24 invalid. 25 26 SECTION 10: The City Council finds that this Ordinance is not subject to the California 27 Environmental Quality Act ( "CEQA ") pursuant to Sections 15060(c) (2) (the activity will not result in 28 a direct or reasonably foreseeable indirect physical change in the environment) and 15060(c) (3) 29 (the activity is not a project'as defined in Section 15378) of the CEQA Guidelines because it has 30 no potential for resulting in physical change to the environment, directly or indirectly. 31 32 SECTION 1.1: This ordinance shall become effective thirty (30) days after the date of its 33 adoption by the Petaluma City Council, and its provisions shall become applicable on January 34 1, 20.1 1. 35, 36 Ordinance No. 2392 N.C.S. Page 41 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22. 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 SECTION 12: The City Clerk is hereby further directed to post and publish this ordinance or a synopsis of this ordinance for the period and in the manner required by the City Charter. INTRODUCED andlordered posted /wed this 15'" day of November, 2010. ADOPTED THIS day of 2010 by the following vote: Ayes: Noes: Abstain: Absent: Pamela Torliatt, Mayor ATTEST: APPROVED AS TO FORM: Claire Cooper, City Clerk Eric W. Danly, City Attorney Ordinance No. 2392 N.C.S. Page 42 1 Exhibit A 2 3 4 FINDINGS OF FACT AND NEED FOR CHANGES OR MODIFICATIOINS 5 TO THE CALIFORNIA FIRE CODE, 2010 EDITION WITH' CALIFORNIA 6 AMENDMENTS, DUE TO LOCAL CONDITIONS 7 8 9 CHANGES OR MODIFICATIONS Pursuant to Section 17958 of the State of California Health and 10 Safety Code, the governing body of the City-of Petaluma in its ordinance adopting and 11 amending the 2010 Edition of the California Fire Code, changes or modifies certain provisions of 12 the California Building Standards Code as it pertains to the regulation of buildings used for 13 human habitation. A copy of the text of such changes or modifications is attached. 14 15 FINDINGS Pursuant to Sections 17958.5' and, 17958.7(a) of the State of California Health and 16 Safety Code, the governing body of the City of;Petaluma.has determined and finds that all the 17 attached changes or modifications are needed and are reasonably necessary because of local 18 climatic, geological and topographic conditions as discussed below. 19 20 LOCAL CONDITIONS Local,conditions have an adverse effect on the prevention of (1) major 21 loss fires, (2) major earthquake, damage, and (3) the potential for life and property loss, making 22 the changes or modifications in the California Fire Code and the State Building Standards Code 23 necessary in order to provide a reasonable degree of property security, and fire and life safety in 24 the City of Petaluma. 25 26 Below are adverse local climatic, geological and topographic conditions that necessitate the 27 modifications to the, California Fire Code and California Building. Standards Code. 28 29 CLIMATIC 30 31 Precipitation Precipitation: ranges 'from twenty inches (20 ") to approximately twenty -five inches 32 (25 ") per year. Approximately ninety percent (90 %) falls during the months of November through 33 April, and ten percent (10 %) from May through October. Severe flooding occurred during the 34 months of January and March, 1995 and in 1998 and 2006. 35 36 Relative Humidity Humidity generally ranges from fifty percent (50 %) during daytime and eighty - 37 six percent (86 %) at night. It drops to twenty percent (20 %) during the summer months and 38 occasionally drops lower during the months of September through November. 39 40 Temperatures Temperatures. have been recorded as high as 104 degrees Fahrenheit. Average 41 summer highs!are in the 78=85 degree range. 42 43 Winds Prevailing winds are from the northwest. However, winds are experienced from virtually 44 every direction at one time or another. Velocities are generally in the 5 -15 mph range, gusting to 45 7.4 -30 mph, particularly during the summer months. Extreme winds, up to 50 mph, have been 46 known to occur. 47 48 Summary These local climatic conditions affect the acceleration, intensity, and size of fires in 49 the community.. Times of little or no rainfall, of low humidity and high temperatures create 50 extremely hazardous conditions, particularly as they relate to wood shake and shingle roof fires 51 and conflagrations. The winds experienced in this area also adversely impact structure fires in Ordinance No. 2392 N.C.S. Page 43 1 buildings in close proximity to one another. Winds can carry sparks and burning branches to 2 ' other structures,, thus spreading the fire and causing conflagrations. In building fires, winds can 3 literally force fires back into the building and create a. blowtorch effect, in addition to 4 preventing "natural" ventilation and cross- ventilation efforts. Petaluma's downtown and 5 surrounding areas contain numerous historic and older buildings that are located very close 6 together, which exacerbates the fire danger from dry conditions, wind, and shake /shingle roofs. 7 8 TOPOGRAPHIC 9 10 The topographic fire environment of a community is primarily the combination of two factors: 11 the area's physical geographic characteristics and the historic pattern of urban - suburban 12 development. These two factors, alone and combined, create a mixture of environments which 13 ultimately determine the areas' fire protection needs. 14 15 The basic geographical boundaries of the city include hills to the south and west, and valley 16 floor in the central area and to the north and east. The Petaluma River bisects the city through 17 the central area. The City of'Petaluma covers thirteen (13) square miles and contains an urban 18 population estimated at 57,000. The city's service area is a conglomeration of bay, plains, hills, 19 valleys, and ridges. Within the city are three (3) fire stations and fifty -six (56) fire personnel. 20 Because of the size of the City of Petaluma, the characteristics of the fire environment changes 21 from one location to the next. For example, the central downtown area contains older buildings 22 situated close together, which, increases the ability of fire to spread from one building to the 23 next. In contrast, some of the properties on the outlying hills are far apart, but contain large 24 grassy acreages that promote quickly- spreading wildfires during the long dry season. 25 26 The city's development pattern also contributes to its unique fire protection needs. 27 Development has traditionally occurred on the flat lands (0 - 5% slope) in the central and 28 eastern portions of the city. However, over the last ten (10) years, development has spread into 29 the hills and the smaller valleys and canyons. This development - has significantly increased the 30 service area for the city's fire department and has added complicated.logistical challenges for 31 getting fire equipment to remote fires or fires on steep hillsides. The majority of the hillsides in 32 these areas have slopes ranging from 15 - 300. As a basic rule of thumb, the rate of spread will 33 double as the slope percentage doubles, all other factors remaining the same. 34 35 The local vegetation further contributes to fire dangers in the city. Petaluma's semi -arid 36 Mediterranean -type climate produces vegetation similar to that' of most of Sonoma County. In 37 the long periods of the year with little or no rain (April through October), this vegetation provides 38 ready fuel for fast - spreading wildfires. 39 40 Moreover, some of the structures in the city have combustible wood- shingle or shake roofs. This 41 very flammable material is susceptible to ignition by embers from a wild land fire, furthering the 42 spread of fire to adjacent buildings. 43 44 GEOLOGICAL 45 46 The above local topographic conditions enhance the magnitude, exposure, accessibility 47 problems, and fire hazards presented to the City of Petaluma. Fire following an earthquake has 48 the potential of causing greater loss of life and damage than the earthquake itself. 49 50 The relatively young geological processes that have created the San Francisco Bay Area are still 51 active today. Two (2) active earthquake faults (San Andreas and the Hayward- Rodgers Creek) Ordinance No. 2392 N.C.S. Page 44 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 affect the Petaluma area. Approximately fifty percent (50 %) of the city's land surface is in the high -to- moderate seismic hazard zones. The majority of'the city's industrial complexes are located in the highest seismic risk zones. The highest seismic risk zone also contains the largest concentration of hazardous materials. Hazard ousrnateriaIs, particularly: toxic gases, could pose the greatest threat to the largest number„ should a significant seismic event occur. The city's resources would have to be prioritized to mitigate the greatest threat, and may likely be unavailable for fires in smaller single- dwellings and structures. Other variables that may intensify the fire danger after a major seismic event include: • The extent of damage to the water system; • The extent of isolation due to bridge and /or freeway overpass collapse; • The extent of roadway damage and /or amount of debris blocking the roadways; • Climatic conditions (hot, dry weather with high winds); • Time of day, which will influence the amount of traffic on roadways and could intensify the risk of life during normal business hours; • The availability of timely mutual aid or as.sista.nce from neighboring departments, which will likely have similar emergencies at the same time; and • The large portion of dwellings with wood shingle roof coverings, which will increase the likelihood of conflagrations. CONCLUSION Local climatic, geological and topographic conditions impact fire protection efforts, and the frequency, spread, acceleration, intensity and size of fire involving buildings in this community. Further, they impact potenfial damage to all structures from earthquake and subsequent fire. Therefore, it is reasonably necessary that the California Fire Code be changed or modified to mitigate the effects of the above conditions. Furthermore, California Health 8 SafetyCode (CH&SC) Section 17958.7 requires that the modification or change to which findings refer be expressly marked and identified. Therefore, the following table provides code sections that will be modified by this ordinance which are building standards as defined in CH&SC Section 18909, and the associated referenced conditions for modification due to local climatic, geologic and topographical conditions. Section Number Local Climatic, Geoloqic and Topographical Conditions 102.3 a, b, c 102.7.1 a, b, c 104.3 a, b, c 104..1 1.4 a, b, c 105.2 a, b, c 109.3 a, b, c 111.4 a, b, c 503.1.1 a, b, c 503.2.1 a, b, c 503.2.3 a, b, c 503.2.4 a, b, c 503.2.6 a, b; c 503.2.6.1 a, b, c 503.2.6.2 a, b, c Ordinance No. 2392 N.C.S. Page 45 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 Section Number Local Climatic, Geologic and Topographical Conditions 503.2.7 503.4 505.1 505.11.1 505..1.2 506.1 507.5 507.5.1 510.1 605:1 1 901.7.7 903.2 903.2.19 903.2.19.1 903.2.19.2 903.2.19.3 903.2.19.4 903.2.19.5 903.2.19.6 903.3 903.3.1 903.3.7 903.4 903.4.1 903.4.2 905.3.1 907.2.8.1 907.2.9.1 2701:5.3 2703.3.1 3301.1 4902.1 4906.2_ 4907 4907.1 Appendix Ch. B 105.1 Appendix Ch B`105.2 Table 0.105.1 f Table C 1'05:1 g. Appendix',Ch..Da1,03:2. Appendix, Ch. D103.3 Appendix Ch. D103.4 Appendix Ch..D103.4.1 Appendix Ch. D103.4.2 Table D103.4 Appendix Ch. D 103.6 Appendix Ch. D 104.2 Appendix Ch. D106.1 Appendix Ch. D 107.1 a, b, c a, b, c a, b, c a, b, c a, c a, b a, b, c a, b, c b, c a, b, c a, b a, b, c a, b, c a, b, c a, b, c a, b, c a, b, c a, b, c a, b, c a, b, c a, b, c a, b, , c a, b, c a, b a, b a, b, c a, b a, b a, b a, b, c a, b, c a, b, c a, b, c a, b, c a, b, c a, b a, b a, b a, b a, b a, b a, b, c a,b,c a, b, c a, b, c a, b a, b a; b a, b Ordinance No. 2392 N.C.S. Page 46